CK1004多线控制器2

 

The Panel is a 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses
conventional input devices. The panel accepts water flow devices, two-wire
smoke detectors, four-wire smoke detectors, pull stations and other
normally-open contact devices. Outputs include four Notification Appliance
Circuits (NAC, SOUND1-4), three standard Form-A relays (alarm, trouble and
supervisory) and an EIA-485 port to interface with remote annunciators and
optional remote relay modules. The FACP is field programmable via the panel
keypad. It also supervises all wiring, AC voltage and battery level.
This series of panels are basically the same in application and operation, their
differences are shown in Table 1-1. The Panel will be described as the example in
the following sections.
Table 1-1
FACP Number of
Detection Zones
Number of
Sounder Outputs
Output Delay
Settings
ZONE-4 4 1 N/A
ZONE-8 8 2 N/A
ZONE-16 16 4 N/A
1.1 Product Features
l 4,8,16 Class B Initiating Device Circuits (IDCs)
? All zones accept conventional detectors and any normally open
contact device
l Four Class B Notification Appliance Circuits (NACs)
l One Form-A Alarm Relay
l One Form-A Trouble Relay
l One Form-A Supervisory Relay
l 3.0 amps of system power
l Max 20 conventional detectors in one zone.
l Auto/Manual mode setting enable walk test.
l Each Zone can be disabled,
l Sound output can be disabled.
l Manual active sound output enabled.

 

 

AC Power
90 to 270 VAC, 50 /60 Hz, 2.3 amps
Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation
Battery (lead acid only)
Maximum Charging Circuit: Normal Flat Charge—27.6V @ 0.8 amp
Maximum Charger Capacity: 18 Amp Hour batter
Sound Output Device Circuits
General Alarm Zones 1 through 16
Operation: All zones Class B
Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum)
Alarm Current: 15 mA threshold
Short Circuit Current: 42 mA maximum
Maximum Loop Resistance: 100 ohms
End-of-Line Resistor: 4.7K, ½ watt
Detector Loop Current is sufficient to ensure operation of two alarmed detectors
per zone
Standby Current: 7.26 mA
Three Relays Output
Relay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC
(resistive)
Nonresettable 24 VDC Power
Maximum ripple voltage: 10 mVRMS Operating Voltage nominal 24 volts
Total DC current available from this output is up to 500 mA
Recommended maximum Standby current is 150 mA

1.4 Circuits
Input Circuits
Sixteen input circuits provide configuration. Input circuits 1 through 16
may be used as standard fire alarm control panel zones. All sixteen
Initiating Device Circuits accept normally-open contact devices and
two-wire smoke detectors.
Output Circuits
• 24 Volt Resettable Power Output 1000 mA
• 24 Volt Nonresettable Power Output 1000 mA
• 24 Volt Battery Charger (up to 18 AH batteries)
• EIA-485 Port (interfaces to Annunciators, and Graphic Annunciators
and Remote Relay Module)
Sound (Notification Appliance )Circuits
Four Notification Appliance Circuits.
Relays
Three dry relays for system alarm, system trouble and supervisory are
provided standard. Contacts are rated 2.0 amps @ 30 VDC (resistive) and
2.0 amps @ 30 VAC (resistive).
EIA-485 Port(Optional)
EIA-485 compatible port supports up to 10 different device addresses which
can consist of Remote Annunciators, Relay Modules, Annunciators or
Graphic Annunciators or any combination of the four modules.
Battery Charger
Battery Charger will charge up to 18 AH batteries. The PANEL cabinet

联系方式 
联系电话     

解先生:

 

QQ:解先生:234745514

 


传真号码:     
阿里旺旺:cszss

官方网站:http://www.cszss.com


规格参数
型号 CK1004   继电器驱动 有  
探头输入方式 接线电流   品牌 convoy  
供电电源 220   通讯方式 烟雾通讯  
环境温度 -10-50   环境湿度≤ 95  
类型 消防报警主机   适用范围 家庭、控制室  
外形尺寸 420x180x170   颜色 红色  
包装参数
体积(m²)
产品重量(kg)
代理商供货
退换货规则说明
申请方式

1,在线申请:您可以在"我的订单"中找到您需要退换修的订单,点击”申请退款/退货”即可。我们的工作人员会在2个工作日 内和您取得联系,你可以随时在线查看你的退换修状态。

注意事项

1,“7天无理由退换货”适用于买家在收到货品后因不满意货品希望退换货的情形。

2,因质量问题产生的退换货,邮费由平台供应商承担(此质量问题为货品破损或残缺)。非商品质量问题的退换货,应由买家承担往返运费。

3,退换货要求退换的商品在平台供应商收到时有完整的外包装、配件、标牌等;待退换的物品被用过、人为破坏或标牌拆卸的不予退换。

(1)符合退货政策的商品必须包装完整、数量准确且不影响再次销售,退货的同时必须退回相应的发票和相关文件。

(2)请对寄回的商品妥善包装,若是退换货过程中由于包装过于简单造成的物流损坏,平台供应商不承担商品完整责任。

(3���发票需单独寄送。退换货时,如涉及发票退回,请您不要将发票放在货物中一起寄送,平台供应商客服人员将和您确认发票寄送地址,避免丢失。

4,退货商品的价款到账时间因支付方式的不同而有所差异,具体应参照相关银行或支付工具的说明提示,平台供应商不对退换货费用的到账时间做任何形式的保证。

特别提醒:为避免由于商品滞留造成的经济损失,所有退换货商品,买家应在所规定之时间内发回(以物流签收时间次日起7天内为准),超过规定时间仍不能将退换商品发出的,平台供应商将不予接受该退换货商品。

联系方式
注意:1 . 使用电话联系可有效保证您的号码隐私不被泄露
          2 . 拨打后可在后台进行拨打记录查询
          3 . 成交后在会员中心确认可获得积分
联系人:梁曰轰 (市场部/市场经理)
电话:18948193571
给我留言
注意:1. 供应商将在24小时内给您回复,回复内容将以短信形式发送至您手机。
2. 对产品的尺寸,质量,规格,库存等方面技术问题进行咨询,我们有专人进行回复,因厂家随时会更改产品的相关信息,请以厂家实际产品为准。
咨询产品:
fire control panel 多线型火灾报警主机 消防报警主机 深圳厂家
联系电话:
联系人:
留言详情: